SQS-series of soft drink mixer
【字体: 】 Click:   
SQS series of steam mixed with water

 Products  SQS series of soft drink mixer is a new energy-saving and environmentally friendly products. It is the use of steam mixed with water directly to the hot water, with a low noise, no vibration, heat exchange efficiency, energy saving features are widely used in daily life, production, heating and hot water heating systems deaerator, The heater nozzle from the main shell, network boards, gaskets and other components. Water is heated through submissions Laval nozzle of the tube, from the steam nozzle through the wall of the lateral oblique many holes sprayed into the water, and both in high-speed flows instantaneous good mix to achieve the purpose of heating water, steam valve regulated side (manual or electric control valve), could be required temperature of hot water.

(1) specifications for different types of heaters, the rated flow capacity, heating temperature of hot water for steam volume can be calculated by the following formula :
D0=D1C1(T2-T1)/(i0"-C2T2)=D1(qT2-qT1)/(i"-C2T2)D0=D1C1 (T2) / (ma "-C2T2) =D1 (qT2-qT1) / (i "-C2T2)
Where : D1- rated flow (t/h) D0-required amount of steam (t/h) T2- heating of the water temperature (° C) C1 T1 water temperature heat (KJ/Kg ℃)
C2-T2 water temperature heat (KJ/Kg C) T1-enter the heater temperature (° C) ma "- enter P0 heater under the pressure of saturated steam enthalpy (KJ/Kg)
(2) Rated to flow and steam pressure of 0.4MPa, with different heating temperature steam consumption of the relationship :
● Open System steam consumption t/h
SQS-SQS- 44 66 88 1010 1212 1616 2020 2424 3232 4040 4848
额定进水Rated influent 流量D1A flow D 1.21.2 2.52.5 4.54.5 7.07.0 1010 1616 2525 3535 6060 105105 165165
加热温差℃Heating temperature ℃ 2020 0.0390.039 0.0810.081 0.146.146 0.2280.228 0.3250.325 0.520.520 0.8130.813 1.138113.8 1.9511.951 3.1453.145 5.3665.366
4040 0.0810.081 0.188.188 0.3030.303 0.471.471 0.672.672 1.0761.076 1.6811.681 2.3532.353 4.0344.034 7.5077.507 11.09211.092
6060 0.1250.125 0.261.261 0.469.469 0.730.730 1.0431.043 1.6691.669 2.6092.609 3.6523.652 6.2616.261 10.95210.952 17.21717.217
8080 0.173.173 0.360.360 0.6490.649 1.0091.009 1.4411.441 2.3062.306 3.6033.603 5.0455.045 8.6498.649 15.13515.135 23.78423.784
●循环系统蒸汽消耗量t/h● circulatory steam consumption t/h
SQS-SQS- 44 66 88 1010 1212 1616 2020 2424 3232 4040 4848
额定进水Rated influent 流量D1A flow D 1.21.2 2.52.5 4.54.5 7.07.0 1010 1616 2525 3535 6060 105105 165165
加热温差℃Heating temperature ℃ 70-9570-95 0.0540.054 0.1120.112 0.2010.201 0.312.312 0.446.446 0.714.714 1.1161.116 1.5621.562 2.6782.678 4.6874.687 7.3667.366
70-11070-110 0.0880.088 0.183.183 0.3300.330 0.514.514 0.734.734 1.1741.174 1.8301.830 2.5692.569 4.4044.404 7.7067.706 12.11012.110
70-13070-130 0.137.137 0.286.286 0.4540.454 0.8000.800 1.1431.143 1.8291.829 2.8572.857 4.0004.000 6.8576.857 12.00012.000 18.80718.807

Installed for use
(1) the use of the equipment conditions :
1. Safe operation conditions : enter the heater steam pressure ---
SQS-4~SQS-24 P0≤1.6MPa, SQS-32~SQS-48 P0≤1.0MPaSQS-4~SQS-24 P0 ≤ 1.6MPa. SQS-32~SQS-48 P0 ≤ 1.0MPa
2. Good operating condition :
SQS-4~SQS-24 P1+0.05 ≤ ≤ 0.6 MPa - P0 : P0------- steam pressure (MPa)
SQS-32~SQS-48 P1+0.05≤P0≤0.35MPa P1
For SQS-32~SQS-48 products in the circulatory system, If higher inlet pressure (≤ not meet P1+0.05 P0 conditions, Heater pumps should be installed in the suction side, using hot water circulating pump, make it a good run. When using superheated steam heat, to reduce noise, or use sub-heating steam temperature.
(2) the application scope :
1. For the hot water heating system for heating equipment to replace the original surface - (indirect) for once. (Figure 4 and Figure 5)
2. Heating water for the bathroom into the water instead of hot water Zhongyuan high noise, Strong vibration of the steam direct heating methods (tube).(Figure 2)
3. Deaerator for preheating soft water (water deaeration). (Figure 3)
(3) installation : the equipment used horizontal or vertical mounting.
SQS-series of soft drink mixer
Figure 2 heating water (open system)
Figure 3 heating water (open system)

(4) the hot water heating system, when the power source for electric pump cycle, the heater can be installed in the water pump side. Chart 4, may also be packed in water pumps to the side, see Figure 5. When the power source for the steam jet pump, the heater can be installed only on the water jet pump side.
SQS-series of soft drink mixer
图四 加热器在水泵出水侧Figure 4 pump water heater in the side
图五 加热器在水泵入水侧Figure 5 heater pumps water into side

(5) in a cycle of electric power to pump the water heating system, the heater installed in the pump inlet side of conditions :
A. Export heater temperature must be below the pump inlet pressure of the boiling temperature, which can not pump inlet vapor;
B. Must be below the pump itself allows temperature.
(6) Use of the system must be set up to the valves, gauges see Schedule;
(7) heater system all valves, meters and the installation location can refer to Figure 4 and 5;
(8) Commitment : 1. In open systems, first the water side of the valve; After the steam valve opening; Stop running, concerned with steam valves, another related water side valves.
2. In the circulatory system, in general, the water pipe valve was opened, only Kai stopped pumping. Therefore put into use, first activate pumps, steam valves after the opening; Stop, concerned with steam valves, pumps after stop.
(9) for the frequent power outages in hot water heating system should be set up road steam pipe high temperature solenoid valve. When an electric, solenoid valve position at room temperature; When the blackout, the solenoid valve in the closed position, cut off the steam source. guarantee system security.
(10) To prevent the water to the steam pipe, the steam pipe near the heater should check valve installed.
(11) loss of water pressure : the installation of the heater circulation pumps in the export side, has not joined the steam, pressure loss 50KPa; when installed in the pump inlet side, has not joined the steam, the pressure of 0.15MPa loss around. Joined the steam temperature, the pressure loss is zero.



                      Schedule : Instrumentation valves provides matching table
  蒸汽侧Steam side 进水侧Influent side 出水侧Water Side
管路阀门仪表使用系统Instrumentation used pipe valve system 截止阀By valve 止回阀Check valve 电磁阀Solenoid Valve 压力表Manometer 调节阀Control Valve 截止阀By valve 压力表Manometer 温度计Thermometer 截止阀By valve 压力表Manometer 温度计Thermometer
热水采暖循环系统Heating water recycling system
浴室用水加热系统Bathroom water heating system          
除氧水预热Deaerator Water Heater

Note : 1. "*" For specific design decide whether or not to use.
2. Heating and whether Deaerator based automatic control by specific design.
3. These complementary product, I plant will provide support.

Notes orders "br> ordering units to use, the manufacturer shall provide the following information to choose reasonable heater.
1. Heating water (or water cycle) D1 (t/h);
2. P0 saturation vapor pressure (MPa);
3. P1 inlet pressure (MPa);
4. T1 inlet temperature (° C);
5. Water temperature T2 (C)

 
 